logo_small.gif (4090 Byte)

 

Multi-Channel / Multi-Spectral detectors
 

PML-16   »16 channel TCSPC Detector« 
 

 

16 Channel TCSPC with bh SPC Modules

Simultaneous Measurement in all 16 channels

1 by 16 Arrangement of Detector Channels

Time Resolution 200 ps FWHM

Operation via bh DCC-100 detector controller

Count Rate up to  4 MHz

Part of the bh Multi-spectral FLIM Detection system

Direct Interfacing to all bh Photon Counting Devices

   

data sheet, operating manual
 

PML-16-0

Bi-alkali version

300-650 nm

 

PML-16-1

Multi-alkali version

300-820 nm

PML-16-GaAsP  »16 channel TCSPC Detector with GaAsP cathode« 
 

 

GaAsP photocathode

16 Channel TCSPC with bh SPC Modules

Simultaneous Measurement in all 16 channels

1 by 16 Arrangement of Detector Channels

Time Resolution 200 ps FWHM

Operation via bh DCC-100 detector controller

Count Rate up to  4 MHz

Part of the bh Multi-spectral FLIM Detection system

Direct Interfacing to all bh Photon Counting Devices

   

operating manual

PML-16-GASP

GaAsP version

360-720 nm

SPAD-8   »8 channel SPAD Module« 
 

 

8-channel SPAD detector module

Simultaneous measurement in all 8 channels

1 by 8 arrangement of detector channels

Instrument response width 70 ps FWHM

Max. count rate >5 MHz

Thermo-electrically cooled

Power supply and control via bh DCC-100 detector controller card

Direct Interfacing to all bh Photon Counting Devices

   

data sheet

PML-Spec   »Multi-spectral lifetime detection« 
 

 

Simultaneous recording of time- and spectral information

16 parallel signal channels

Input for optical fibres ( SMA-905 )

Connects directly to SPC modules and Simple-Tau

   
   
   
   
   

Data sheet

PML-Spec-GaAsP   »Multi-spectral lifetime detection with GaAsP cathode« 
 

 

 

GaAsP cathode

Simultaneous recording of time- and spectral information

16 parallel signal channels

Input for optical fibres ( SMA-905 )

Connects directly to SPC modules and Simple-Tau

   
   
   
   
   

 Handbook

MW-FLIM   »Multi-Wavelength FLIM Detector for microscopy« 
 

 

Parallel detection of 16 FLIM images
in 16 wavelength intervals

No wavelength scanning

No wavelength scanning artifacts

Controlled via bh DCC-100

Internal generator for PMT operating
voltage

Available for confocal microscope and
multiphoton microscopes with
non-descanned detection

Target applications: Autofluorescence
imaging of cells and tissue, combination of
FLIM-FRET and spectral FRET Techniques

   
   
   
   
   

Data sheet,  Handbook, Handbook Zeiss FLIM

 

MW-FLIM-GaAsP   »Multi-Wavelength FLIM Detector, GaAsP Cathode« 
 

 

High efficieny GaAsP cathode

Parallel detection of 16 FLIM images
in 16 wavelength intervals

No wavelength scanning

No wavelength scanning artifacts

Controlled via bh DCC-100

Internal generator for PMT operating
voltage

Available for confocal microscope and
multiphoton microscopes with
non-descanned detection

Target applications: Autofluorescence
imaging of cells and tissue, combination of
FLIM-FRET and spectral FRET Techniques

   
   
   
   
   

Data sheet,  Handbook, Handbook Zeiss FLIM

 

 

      

 

 

 


 

 

©1993-2017
Becker & Hickl GmbH
Nahmitzer Damm 30
12277 Berlin

Geschäftsführer: Dr. Wolfgang Becker

Amtsgericht Berlin-Charlottenburg HRB 50729
USt-ID Nr: DE164939770
 

email info@becker-hickl.com
fon +49 (30) 212 80 02-0
fax +49 (30) 212 80 02-13